
Energy Efficiency Solutions for Cooling Systems
Discover how GPAEE New Technologies Blitz offers innovative energy-saving solutions for chillers and cooling systems, including automatic tube cleaning systems, filtration options, free cooling upgrades, and more. Save money, improve efficiency, and reduce environmental impact with these cutting-edge technologies.
Download Presentation

Please find below an Image/Link to download the presentation.
The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author. If you encounter any issues during the download, it is possible that the publisher has removed the file from their server.
You are allowed to download the files provided on this website for personal or commercial use, subject to the condition that they are used lawfully. All files are the property of their respective owners.
The content on the website is provided AS IS for your information and personal use only. It may not be sold, licensed, or shared on other websites without obtaining consent from the author.
E N D
Presentation Transcript
GPAEE New Technologies Blitz MERION MERION 960 Brook Road, Unit 3, Conshohocken, PA 19428 * Phone: (610) 825-5040 * Fax: (610) 825-5080 *
Energy Savers Automatic Tube Brush Cleaning System for Chillers Clean Condenser Water tubes yield 15 % energy savings versus fouled tubes Manual seasonal tube brushing is the standard operating procedure for most chillers. However in as little as two weeks time, tubes return to "dirty state and their increased pressure drops and inefficiencies return to end of the season conditions. These values will be verified in chiller logs.
Reversing valve also applied to Plate Heat Exchangers reverse of flow dis-lodges dirt buildup
Energy Savers FILTRATION Dirt in your cooling system acts as an insulator creating inefficient heat transfer requiring more energy for your system to operate effectively. How can we remove dirt particles????? Hydro-Cyclone Particle Separator - removes particles - 40 microns and larger from your flow stream. Sand filtration removes particles down to 5 microns. Bag filters removes particles down to 1 micron. Continual attention by maintenance staff required.
Energy Savers FREE COOLING Adding a plate & frame heat exchanger, two (2) 3-way motor-operated valves, and a control panel - between your cooling tower and chiller eliminates 2000 to 3000 hours of chiller operation annually. System pay-back in as little as one season.
Energy Savers STOP Wasting Money with closed-circuit coolers. Replace an evaporative cooler with an open cooling tower, plate & frame heat exchanger, and circulating pump. Initial cost savings of equipment 25 to 30% Energy savings of 45 to 50% annually Fiberglass cooling tower with PHE/pump system offers additional life expectancies over 2X that of an evaporative cooler.